yellow jacket 37880 manual


Weight w/o refrigerantApproximately 220 lbs. If the unit fails the second time follow the on screen instructions and take the appropriate steps to remove the contaminated refrigerant with a separate unit for removal of contaminated refrigerant. Holding the button depressed will increase the rate of change. After the system turns off, the unit will beep to alert the technician the job is complete. In Charge mode, how- ever, accuracy is plus or minus 1/2 ounce based on variations in air temperature and pressure. RESET- Press RESET to cancel the current opera- tion. If the refrigerant does not pass the identification proc- ess (98% purity) the unit will display the error message CONTAMINATED and the screen will show the re- sults of the identification. The status indicator LED will flash green. Do not use equipment in the vicinity of spilled or open containers of gasoline or other ammable substances. Failure to insure that hoses, o-rings and fittings are in working order can increase a build-up of NCGs in the recovered refrigerant. To obtain pressure readings in a snap, each RMS unit comes with a YELLOW JACKET ManTooth Wireless Digital Pressure/Temperature Gauge so you can test the A/C system without losing refrigerant. 9. This adapter connects the low side auto service coupling to the tank of new R- 134a refrigerant. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. Refrigerant measurement during charging is extremely accurate. Your email address will not be published. For instance, if the system needs to be opened to atmos- phere to replace a part, all refrigerant must be removed before opening the system. Therefore, problems related to non-maintained oil will void this warranty on that part of the product. Charge accuracy within 1/2 oz.

All hoses may contain liquid refrigerant under pressure. items. If the filter begins to turn red in color stop using the re- frigerant identifier immediately. Most states, countries, etc., may require user to be licensed. For all other products, please return warranty items to the main factory in Bloomington, MN, prepaid for credit, replacement, or repair, at our option. 3. The unit is now ready for operation. NOTE: If desired, the gauges of the 880 SERIES can now be used to aid investigation of an A/C sys- tem problem. Home YELLOW JACKET YELLOW JACKET 95780 Turbo Recover Refrigerant Recovery Machine User Guide, YJACKTM Series - Bluetooth Sensing Technology 67060, 67061, 67062, 67063, 67070, 67071, 40877 Quick Start Guide Power on, Yellow Jacket 52030F Thermal Imager Operating Instructions Manual - Download [optimized] Yellow Jacket 52030F Thermal Imager Operating Instructions, YELLOW JACKET Digital Manifold User Guide Key Function ON / OFF key: power on/off and refrigerant switch. Special production items will have a higher restocking charge. Open Refrigerant Storage Tanks liquid valve. 4. Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. 2. Ganhe 10 pontos por cada documento compartilhado e mais pontos a cada novo download recebido, Obtenha Pontos de Download para cada documento compartilhado, Ajude outros alunos e ganhe 10 pontos para cada resposta dada, Obtenha pontos premium para baixar documentos compartilhados e documentos Store sem esperar, Mtodo de Estudo Definitivo E-book Docsity, Guia Eficaz para Esquemas e Mapas Mentais, O guia para melhorar a sua autoconfiana, Manuais, Projetos, Pesquisas de Psicologia, Pea ajuda comunidade e tire suas dvidas relacionadas ao estudo, Descubra as melhores universidades em seu pas de acordo com os usurios da Docsity, Centro Universitrio do Leste de Minas Gerais (UNILESTEMG). 12 Purging Non-Condensable Gases The 37880 is designed to automatically purge non- condesable gases such as air present in the storage tank. Press MODE 2 for Vacuum. hose, 5 cfm vacuum pump and Android tablet. Fully factory tested 34-point quality check. Over-lled recovery cylinders can explode causing severe injury and property damage. The LCD should read CHECK OIL LEVELS. 8. No authorization is required. Tablet follows manufacturers warranty. Attach the tank refill adapter (Part No. WARRANTY RETURNS - For HVAC&R Recovery Units and for Automotive Recovery, Recycle, Recharge equipment, call 1-800-769-8370 for instructions for service, repair, or return. Close the service valves and disconnect the high and low side auto service hoses from the automobile. NON-WARRANTY RETURNS - Prior authorization must be obtained from home office for non-warranty returns. Press the RESET key to return to SELECT MODE. The LCD will read CONNECT HOSES PRESS ENTER TO CONTINUE 5. 37880 Series Refrigerant Management System Section Page Section Page Specifications 2 MODE 6: Tank Refill 10 Safety Instructions 3 MODE 7: Refrigerant Management System 11 Component Diagram 4 Purging Non-Condensable Gases 12 Control Panel Overview 5 Maintenance Reminders 12 Setup/Check List/User Options 6 Filter change/compressor oil/vacuum oil 13 MODE 1: Recovery Only 6 Troubleshooting Information 14 MODE 2: Vacuum 7 Common Problems 14 MODE 3: Charge Only 8 LCD Error Messages 15 MODE 4: Full Cycle 9 Repair Parts List 16 MODE 5: Oil Inject 10 Warranty Information 16 Table of Contents Specifications 5 LCD Display The Liquid Crystal Display (LCD) display provides the unit operator with continual updates of the status of the 37880. Pesquise entre todos os recursos de estudo, Estude com provas passadas, TCCs e dicas teis. If the RECOVERY HOLD option is not selected the unit will shut off at the required level of vacuum and the opera- tor must insure that the EPA standard (SAE J2211) is met. Press the ENTER key. MODE 2 Operational Steps 1. The current purge status is displayed in the upper right corner of the LCD when in Select Mode. Shop Electronics & Diagnostics with everyday low prices and fast shipping. Weight - Shows the weight of refrigerant being processed in each mode. Mode 4 Full Cycle, cont. Shop Shop All with everyday low prices and fast shipping. Built for the workingman. JB Tools commitment to 100% customer satisfaction is unparalleled, which is why JB Tools offers its customers a best-in-class Warranty Program to all of its customers on all products sold by JB Tools. Press the ENTER button 4. Mode 1 Recovery Only, cont. Prepare-se para as provas da melhor maneira possvel, Automatic Refrigerant Recovery/Recycling/Recharge System Model 37880 Operation Manual For Automotive Applications YELLOW JACKET 2 Refrigerants: All Models: R-134a Compressor: 1/2 HP Hermetic Compressor Power Source: 120V AC 60Hz for US Models 230V AC 50Hz for CE Models Amperage: RLA: 8.5 RLA: FLA: 11.0 FLA: LRA: 30.0 LRA: 19.0 Size: 37880 Height: 45 inches Width: 19.5 inches Depth: 29 inches Weight: Maximum is deluxe unit at 225 lb. Press START key to begin vacuum and charging operations. However, JB Tools customers can rest assured that JB Tools stands behind its Warranty Program and its Manufacturer Matching Policy,100% of the time. If the refrigerant does not pass the identification process (98% purity) the unit will display the error message CONTAMINATED and the screen will show the results of the identification. Always know how much refrigerant is in your cylinder and how much is in the system to be serviced. The purge time is set to 30 seconds to minimize refrigerant loss. Automatic shut-off for full tank and high pressure situations. Wear proper personal protective equipment such as safety goggles and gloves. 19153) to the R-134a virgin cylinder. MODE 3 - Charge Only, adds refrigerant to an A/C system and is most commonly used to top off the system. Purchase the 37840 for R-134a today and we can update it to R-1234yf later with our optional (one time use) conversion kit. Shop Climate Control with everyday low prices and fast shipping. 1. 10 Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the process. Turn selector knob clockwise to PURGE. With the systems Windows-based control tablet, we can remotely access your machine and provide training to show you how to use the machine and navigate the screens. MODE 7 - Refrigerant Management System, gives the technician access to information about refrigerant use to date. Hoses and 5 CFM Vacuum Pump, Certified to SAE J3030 (37840 includes SAE J2788 and 37860 includes SAEJ2843). Tire suas dvidas lendo as respostas dadas por outros alunos como voc. Verify the message on the LCD reads RECOVERY COMPLETE. 7. (14 grams). Responda perguntas de provas passadas e avalie sua preparao. Easy tank access for quick removal and changeout. LIT, YELLOW JACKET Electric/Manual Lightweight Flaring Tool Instructions Flaring Instructions Step 1: Use a reamer to clean the tube.. Fully automatic air purging constantly monitors and purges non-condensables. Decomposition products are hazardous. The LCD shows error codes for rapid di- agnosis of abnormal conditions. The screens contain the following information: Screen 1: Last Job Information Run Time Refrigerant Recovered Refrigerant Charged Refrigerant Added Screen 2: Year-to-date Information Total Run Time Total Amount Recovered Total Amount Charged Refrigerant Added New WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. Always use the TurboRecover Recovery Machine within its design parameters. An N in the window indicates a purge is not needed. The Recovery Only mode should be used to fully recovery and recycle all refrigerant from an air conditioning system. 4. If the unit continues to display Y or an E and the tank pressure is near the value in the table below, contact Ritchie Engineering Customer Service at (800)769-8370. Press the RESET button. 50 pound storage tank (3784x) and 30 pound storage tank (3786x). LP SWITCH OPENED DURRING VAC- UUM HOLD REPEAT VACUUM CYCLE ERROR 14 LEAK CHECK FAILD FAILED TO HOLD VACUUM AFTER 5 ATTEMPTS REPEAT RECOVERY PROCESS CHECK FOR LEAKS ERROR 15 SYSTEM MAL- EEP-ROM Data read/write error REPLACE MICROPROCESSOR 16 37880 Repair Parts List Part # Description 95423 High Pressure Switch 95180 Vacuum Switch W/COMP Capacitor W/COMP Relay 38026 Differential Switch 38111 Membrane Touch Pad Microprocessor 95157 Circuit Breaker, 15 Amp 68826 Automatic Scale Assembly Part # Description 27296 R-134a Auto Low Side Blue Hose (10ft) 27696 R-134a Auto High Side Red Hose (10ft) 00849 R-134a Tank Vapor Blue Hose (30in) 00853 R-134a Tank Liquid Red Hose (30in) 19153 R-134a Tank Refill Adapter 95006 50lb Refrigerant Tank 38003 Filter-Dryer (1 per unit) 38019 Oil Bottle 38053 Service Compressor Ritchie Engineering Co., Inc. Recovery Division 6701 W. 110th St. Bloomington, MN 55438 USA Phone: 952-943-1333 Toll Free: 800-769-8370 Fax: 952-943-1605 Toll Free: 800-322-8684 E-mail: custserv@yellowjacket.com Web Site: www.yellowjacket.com Warranty Information LIMITED WARRANTY Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which would affect the life of the product under normal use for the purpose for which it was designed. Rotate the front of the vacuum pump out to expose the oil fill port. Turn the selector knob to the RECOVER position. Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the proc- ess. All prices are in USD 2022 JB Tools Inc. Genius Ecommerce by 1Digital. The software in this system is designed to ensure the highest possible accuracy in managing refrigerant usage. Ensure the automobile A/C system is turned off prior to selecting a mode on the ma- chine. See the Purging Non-Condensable Gas section for further details. The LCD should read CONNECT HOSES ENTER TO CONTINUE. NOTE: If desired, the gauges of the 37880 SERIES can now be used to aid investigation of an A/C system problem. 10-foot premium YELLOW JACKET PLUS II hoses for easy connection to even hard-to-reach fittings 25% longer than the standard (15 on 37844). Connect the high and low side auto service hoses to the respective high and low side service ports on the automobile A/C system. Measure the oil in the oil drain bottle. WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. Shop Battery & Charging Systems with everyday low prices and fast shipping. When we decide to sell items for less than the suggested price, the sale price can only be shown in your cart. An N indicates non-condensable gases are below the set limit. Shop Paint, Body & Exterior with everyday low prices and fast shipping. Utilizes manual ball valves in place of solenoids making the AR2700 impervious to contamination andsealants. Because JB Tools is an independent re-seller, JB Tools is able to offer the products it sells at the most competitive prices, resulting in substantial cost-savings passed directly to JB Tools customers. This mode will then proceed to recharge the A/C system. Failure to follow these procedures could void all warranties. The unit will prompt you when it is near the end of its life. This mode also allows the tech- nician to verify the A/C system will hold a vacuum for a certain length of time. Press the Reset key and fol- low the instructions on the screen and the unit will clear itself automatically. An E indicates the unit purged for thirty (30) seconds and non- condensable gases are still present. Timer will count down to display the time left. Furthermore, in connection with JB Tools satisfaction guarantee, JB Tools matches the price and/or any promotion associated with its products. This warranty does not cover abuse, damage from over tightening valves, or broken gauges. Follow the user prompts to complete the tank refill process. Failure to replace the filter will cause damage to the refrigerant identifier and void all warranties related to the refrigerant identifier. Avoid cross-contamination of refrigerant. Maintenance Reminders Approximate Pressure (psig) Temp (F) R-12 R-134a 65 74 74 70 80 81 75 87 88 80 96 97 85 102 115 Temp (F) R-12 R-134a 90 110 120 95 118 126 100 127 135 105 136 145 110 146 155 FILTER - MAINT-FILTER CHG DUE The 37880 has a unique filter system which ensures the refrigerant transferred to the storage cylinder is clean and moisture-free. Mode 2 Vacuum The vacuum function of the 880 SERIES is designed to remove air/moisture from the automobile A/C system by pulling a deep vacuum. Always ensure proper ventilation. Uses of the refrigerant data include: Improved record keeping Accurate determination of net profits Reduced billing errors Minimized refrigerant loss from leaks and theft Reduced operator errors The refrigerant management information is stored in eight registers. To access the information, press Mode 7, REFRIGERANT MANAGEMENT SYSTEM. Many items shown in our price list are custom-fabricated to customers order. 16 cubic inch drier w/ moisture indicator, .7 micron oilseparator, Ball Type Valves to control HI, LO, Recover, andVacuum, 1" Heavy duty tubular frame construction with 10" pneumatic wheels, 4.5" swivelcasters, R134a, R12, R22, R502, R404a, R402a, R401a, R 407c,R409a. On direct drive pumps, many of the problems can be solved over the telephone. You must understand the proce- dures outlined in this manual. If the pressure rises to 0 psi the compressor will restart and the unit will pull down to the required 6 of mercury and hold for two minutes. Press MODE 1 for recovery operations. Connect refrigerant hoses as shown in the diagram and purge air. MODE 4 - Full Cycle, performs a complete recov- ery, recycling, evacuating and charging of an automobile A/C system. The 37880 Series units are covered by a one year parts and labor warranty. Shop Specialty Tools with everyday low prices and fast shipping. Open the service hose valves. Because JB Tools only sells genuine and authentic products, JB Tools offers its customers a 100% satisfaction guarantee. Because a small amount of gas will be released as the oil drains, a small hissing sound may come from the bottle. Always disconnect the power source when servicing this equipment. 5cfm vacuum pump capable of extended pull time periods (7 cfm on 37844). When adding R-134a to the tank of either a 37880, you will need to use the tank refill adapter sup- plied in the accessory kit. Release the button and press ENTER to accept the vacuum time shown on the LCD. Verify the auto air conditioning system is off. An E will display on the LCD if the previous purge was insufficient to lower the non-condensable gas value below the limit. If yes is selected the unit will begin the refrigerant identification process. Shop Power Tools with everyday low prices and fast shipping. Step 1: FILL VACUUM PUMP WITH OIL 1. 6. Inhalation of high concentration of refrigerant vapors is harmful and may cause heart irregu- larities, unconsciousness, or death. Note: Hoses are Date Coded to help determine age of hose. Filter Change Procedure if Filter Lock Out is reached. Comment document.getElementById("comment").setAttribute("id","aafdb627a469eb6dd8cda9e18b7c0728");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. This is a safety feature which prevents excess purging when a malfunction occurs somewhere in the system. Call 952-943-1333. Yellow Jacket 37840 Refrigerant Management System Automatic for R-134a. Holding the button depressed will increase the rate of change. Connect the high and low side auto service hoses to the respective high and low side service ports on the automobile A/C system. The choices are: pounds/ounces, pounds, ounces, and kilograms. Two-stage,5 cfm vacuum pump for fast, high efficiency evacuation (7 cfm on 37844). When the pressure in the tank exceeds a treshold value, the unit will automatically purge the excess pressure. Replace the oil fill cap. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. Dispose of recovered oil in a proper manner. Logging and storage of jobs for future reference and refrigerant usage. 5. When the display reads WARNING: MAINTE- NANCE - CHANGE FILTER DRIER Press Enter key to enter filter change mode. Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the proc- ess. When the display reads WARNING: MAINTE- NANCE - CHANGE FILTER DRIER IN XX.XX LB, press the RESET key to continue. Four magnetic surfaces and magnets to mount notes/hold items. The free downloadable app wirelessly calculates and displays the A/C systems actual pressures in an easy-to-read color format on the RMS tablet, as well as iOS or Android devices. Purge - A Y in this field indicates non- condensable gases such as air are present in the storage tank. In addition, the display will prompt the technician for the user input needed to continue operation. Mode 1 Recovery Only 7 6. Remove the fill cap located on top of the vacuum pump. Rotate the vacuum pump back into its original position and replace the thumbscrews.