Question How do I setup the 4 to 20 mA output in the F601 ? Water and dust-tight (NEMA 4); resistant against oil, Li-Ion battery provides up to 14 hours of measurement, Automatic loading of calibration data and transducer. Our application engineers will be pleased to advise you. Each of these outputs can be uniquely configured by the end user to match the current application. Evensturdier than its predecessor, F601 is ideally suited to the ______ ______ ______ Select a suitable measuring point.______ Simply select the pipe material from the list and measure the wall thickness with the ultrasonic probe.______ Automatic transducer detection and calibration in the device offer maximum safety and ease of use.______ 4 >, ______ Select pipe material and fluid from the integrated list; input the pipe dimensions as requested.______ ______ ______ Apply coupling agent; mount thetransducers on the side of the pipe; set and fix the displayed transducer distance.______ Immediately after the ENTER buttonhas been pressed, the measured values appear in the display.______ 5 >. This document can be downloaded here. Flow measurements in less than a minute with the Flexim ADM6725Series. Special accessories are possible. No cuttinginto the pipe or process interruption is required for installation. Various forms of raw and manipulated data can be stored and recovered with the EESiData software application that will accompany every F601. Answer The F601 is capable of outputting data via RS232 Serial Port, via two analog (4 to 20 mA) ports or two digital (binary) output portss.
Answer A document detailing the procedures required to setup the 4 to 20 mA current output features of the F601 can be downloaded here. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Answer The Quick Start Guide for the F601 can be downloaded here. 2022All rights reserved Question How do I setup the data logging feature of the F601 . FLUXUS FLUXUS > F601 measures the flow ofliquids using FLEXIM's proven transit-time correlation technique. The complete measuring system and the required accessories fit into a sturdy protective transport case. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Answer The F601 is capable of storing 100,000 data sets in time stamped data. Every- where, controlling and balancing the flowof energy is of utmost importance for costconscious users: for the heat delivery from central heating plants to the end user, for the cold supply in a building's cooling systems, for heat transfer flows in industrial processes, etc. Question Where should I mount the transducers ? Close the lid and never worry about the weather. 20122022, manualsdir.comAll rights reserved. Easily get a signal and then press Enter to get the flow rate. A few more simple steps and you'll be gathering accurate data. -, FLEXIM Flexible Industriemesstechnik GmbH, Ultrasonic Flow Meters for Liquids and Gases and Process Analysers, All FLEXIM Flexible Industriemesstechnik GmbH catalogs and technical brochures, FLUXUS WD Series - Non-invasive Water Flow and Temperature Monitoring, Ultrasonic Flow Measurement in Gas Storage Operations, FLUXUS WD - Precise monitoring of district metered areas (DMAs), Non-invasive water and wastewater flow measurement, FLUXUS F808 - Non-intrusive Ultrasonic Clamp-on Flow Measurement for Hazardous Areas, Non-intrusive water and wastewater ? To get a quotation, fill in the online quotation form. It is capable of storing 100,000 measurements, and making data available via RS232, analog (4 to 20 mA) and digital (binary) outputs. Question - Can I adjust the 4-20 mA outputs ? Question - What type of outputs does the F601 have ? Answer The Operations Manual for the F601 can be downloaded here. You can review the price and details of the Flexim 77076G-44 USER MANUAL, ENGLISH product with Flexim, product code 77076G-44 below. ______ reliable measurement even in difficult conditions thanks to the new HybridTrek mode high accuracy thanks to dual P technology with digital signal processing and to powerful correction algorithms maximum flexibility - broad range of applications quick measurement; reliable results in less than 5 minutes sturdy build for use in rough environments ergonomic design; optimized for daily use on-site long-life marathon battery; comprehensive energy management with display of remaining capacity > 2 size="-1">.
Answer regardless of the Pipe or Transducer size, the F601 will measure flows from 0.4 in/sec to 65 ft/sec in all fluids. Question - Where is the Rental Agreement Form for the F601 ? Special ultrasonic transducers are simply clamped onto the outside of the pipe and never come indirect contact with the liquid. Answer - The F601will measure liquid flow through pipes ranging in size from inch to 256 inches in diameter through 4 different transducer sizes. Copyright 2022im-tek.com.tr | All Rights Reserved. Answer Simply plugging the battery charger into any wall socket and into the top of the F601 will begin the charging process. Answer - the Rental Agreement Form for the F601 can be found here. Answer - The F601 is capable of measuring the flow of most liquids through any type of rigid piping or tubing, including all stainless, carbon, Hastelloy, titanium, glass, fiberglass, PVC, PTFE and numerous others. Flexim FLUXUS G721 GAS ULTRASONIC FLOW METER FOR PERMANENT, Flexim 721037-2 PIPE MOUNTING KIT/ STAINLESS STEEL 316L, Flexim 772240-44 MODULE,COMMUNICATION,MODBUS, Flexim 770221-2 0/4 TO 20 mA/ CURRENT OUTPUT, Flexim 770221-1 0/4 TO 20 mA/ CURRENT OUTPUT, Flexim 740255-T ADDITIONAL TEMPERATURE INPUT, Flexim 750G15-2A2 Clamp-on ultrasonic flowmeter. In the Energy version, the > F601 measures the instanta-neous thermal output of a system, i.e. ______ compact and easy to handle______ equally suitable for left and right-handed persons______ designed for industrial use______ multi-functional carrying and set-up handle______ degree of protection IP65______ handles also protect the edges______ low weight______ water and dust-tight; resistant against oil, many liquids, and dirt ______ QuickFix pipe mounting system forfast mounting of the transmitter in positions where a free hand for hol- ding is unavailable (e.g.formeasure- ments in great heights)______ > ______ integrated pipe wall thickness measurement______ ______ precise display of remaining capacity______ more than 14 hours of measurementwith lithium-ion batteries ______ no self-discharge, no memory effect ______ > extensive fluid and material database______ ______ extremely sturdy case; may even be used as a step______ proven FLUXUS > electronics with DSP and dual P, high sampling rate, adaptive signal processing______ increased accuracy in non-ideal con-ditions thanks to new algorithms, e.g.for the correction of pipe wall echoes and transducer positioning errors ______ intuitive stowing and finding of all components ______ FLUXUS FLUXUS In times of rising energy prices and envi-ronmental regulations, optimization of energy flow is a most crucial issue. Question - What is included in the F601 Rental Kit ?
Question - What are the Min/Max flow rates the F601 can measure ? Software FluxData, RS232 and USB cables Manual and quick-start guide > Please see the price lists for details on the scope of delivery and the accessories. The case's dimensions are in accordancewith airline requirements for carry-on luggage. ow measurement, FLUXUS F- ultrasonic flowmeters for liquids, G601 CA Energy - The portable flow meter for the measurement of compressed air, gases and heat quantities, FLUXUS BTU Serie Ultrasonic Flowmeter for measuring non-intrusive energy, Non-Intrusive Flow Measurement for Liquids and Gases in the Upstream Industry, FLUXUS HPI Series Non-Intrusive Ultrasonic Flow Measurement for the Hydrocarbon Processing Industries, Advanced Metering Technology Ultrasonic Flow Measurement in Gas Storage Operations, Non-Intrusive Flow Measurement up to 400C, FLUXUS WD / FLUXUS WS - Monitoring flow in Prestressed Concrete Cylinder Pipes (PCCP), FLUXUS WD The efficient flow monitoring solution. Question - Where are the Quick Start Guides for the F601 ? Answer The 4-20 mA outputs of the F601 can be user adjusted to any range of values youd like. The numerous improvements implemented were derivedfrom years of application practice. Measuring tape Power adapter / charging unit Coupling compound Mounting fixture for the transducers Wall thickness probe QuickFix pipe mounting system for the *Prices are pre-tax. Answer A document detailing the setup and management of the Data Logging features inside the F601 can be downloaded here. Question - What type of pipes will the F601 measure ? Question - Where are the Specifications for the F601 Flow Meter? Answer - The F601 is a dual-channel, dual mode clamp-on liquid ultrasonic flow meter capable of measuring liquid flow through two different pipes from inch to 256 inch in diameter, at the same time, in either Doppler or Transit Time modes. Answer Before making measurements with the F601 you must know the Outside Diameter and Wall Thickness of the pipe youre measuring, plus the approximate temperature of the fluid inside. Question - Where are the Manuals for the F601 ? Question What are the advantages of using the F601? detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results, User-friendly design Transducers available for a wide range of inner pipe, Probe for wall thickness measurement available Robust, water-tight (NEMA 4) transport case with com-, QuickFix for fast mounting of the flow transmitter in diffi-, Designed for industrial use in harsh environments, in gas, processing and natural gas extraction, chemical industry, and in the petroleum industry. Question Can the F601 function as an Energy Meter ? Question - What will I need to know before installing the F601 ? Question - What size pipes will the F601 measure ? During Covid-19 please call: 717-697-8546 or 717-514-4952. Answer The Rental Kit for the F601 will contain the F601 Flow Computer, a pair of Transducers to matchthe pipe sizes you indicate in the Rental Agreement Form, a battery charger/wall adapter, acoustic coupling compound, Mounting Chains and Mounting Clips, Instruction Manuals, Quick Start Guides, EESiData software for Windows, communications (RS232) cabling. Measurement with transducers mounted by the portable Variofix VP, Portable Ultrasonic Flow Measurement of Gas, Portable instrument for non-intrusive, quick ultrasonic flow measurement with clamp-on technology for all, Precise bi-directional and highly dynamic flow measure-, ment with the non-intrusive clamp-on technology, High precision at fast and slow flow rates, high tem-, Portable, easy-to-use flow transmitter with 2 flow chan-, nels, multiple inputs/outputs, an integrated data logger. > F601 is more than just anupgrade to the FLUXUS ADM 6725, an instrument which has proven itself in thousands of applications. Answer - When combined with the optional clamp-on temperature sensors, the F601 is capable of calculating generated or consumed energy in Watts or Jules. Once you input these values into the F601 it will recommend a transducer mounting separation distance. A single pair of S transducers will measure pipes from inch to 1 inches in diameter, Q transducers will measure pipes from 1 to 16 in diameter; M transducers will measure pipes from 4 to 100 inches in diameter and a pair of K transducers will measure pipes from 4 inch to 256 inches in diameter. the flow of heat or cold. Question How do I charge the batteries in the F601 ? Thanks to an integrat- edtotalizer, FLUXUS may also be used as ______Unmatched in performance, the handyand versatile ______ FLUXUS > F601 is ideallysuited for service and maintenance activi- ties, for instance when commissioning systems, for the maintenance and inspec-tion of permanently installed measuringinstrument, for checking pumps or control valves, or as a temporary substitute for defective instruments. Answer A three page document shows you the optimal mounting location for securing transducers onto pipes. Practical applications: Measurement on natural gas pipelines and in natural, Measurement of synthesized gas and injection gas Measurement for the gas supply industry Supervision of permanently installed meters, service.
Answer A document detailing the procedures required to setup the 4 to 20 mA current output features of the F601 can be downloaded here. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Answer The Quick Start Guide for the F601 can be downloaded here. 2022All rights reserved Question How do I setup the data logging feature of the F601 . FLUXUS FLUXUS > F601 measures the flow ofliquids using FLEXIM's proven transit-time correlation technique. The complete measuring system and the required accessories fit into a sturdy protective transport case. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Answer The F601 is capable of storing 100,000 data sets in time stamped data. Every- where, controlling and balancing the flowof energy is of utmost importance for costconscious users: for the heat delivery from central heating plants to the end user, for the cold supply in a building's cooling systems, for heat transfer flows in industrial processes, etc. Question Where should I mount the transducers ? Close the lid and never worry about the weather. 20122022, manualsdir.comAll rights reserved. Easily get a signal and then press Enter to get the flow rate. A few more simple steps and you'll be gathering accurate data. -, FLEXIM Flexible Industriemesstechnik GmbH, Ultrasonic Flow Meters for Liquids and Gases and Process Analysers, All FLEXIM Flexible Industriemesstechnik GmbH catalogs and technical brochures, FLUXUS WD Series - Non-invasive Water Flow and Temperature Monitoring, Ultrasonic Flow Measurement in Gas Storage Operations, FLUXUS WD - Precise monitoring of district metered areas (DMAs), Non-invasive water and wastewater flow measurement, FLUXUS F808 - Non-intrusive Ultrasonic Clamp-on Flow Measurement for Hazardous Areas, Non-intrusive water and wastewater ? To get a quotation, fill in the online quotation form. It is capable of storing 100,000 measurements, and making data available via RS232, analog (4 to 20 mA) and digital (binary) outputs. Question - Can I adjust the 4-20 mA outputs ? Question - What type of outputs does the F601 have ? Answer The Operations Manual for the F601 can be downloaded here. You can review the price and details of the Flexim 77076G-44 USER MANUAL, ENGLISH product with Flexim, product code 77076G-44 below. ______ reliable measurement even in difficult conditions thanks to the new HybridTrek mode high accuracy thanks to dual P technology with digital signal processing and to powerful correction algorithms maximum flexibility - broad range of applications quick measurement; reliable results in less than 5 minutes sturdy build for use in rough environments ergonomic design; optimized for daily use on-site long-life marathon battery; comprehensive energy management with display of remaining capacity > 2 size="-1">.
Answer regardless of the Pipe or Transducer size, the F601 will measure flows from 0.4 in/sec to 65 ft/sec in all fluids. Question - Where is the Rental Agreement Form for the F601 ? Special ultrasonic transducers are simply clamped onto the outside of the pipe and never come indirect contact with the liquid. Answer - The F601will measure liquid flow through pipes ranging in size from inch to 256 inches in diameter through 4 different transducer sizes. Copyright 2022im-tek.com.tr | All Rights Reserved. Answer Simply plugging the battery charger into any wall socket and into the top of the F601 will begin the charging process. Answer - the Rental Agreement Form for the F601 can be found here. Answer - The F601 is capable of measuring the flow of most liquids through any type of rigid piping or tubing, including all stainless, carbon, Hastelloy, titanium, glass, fiberglass, PVC, PTFE and numerous others. Flexim FLUXUS G721 GAS ULTRASONIC FLOW METER FOR PERMANENT, Flexim 721037-2 PIPE MOUNTING KIT/ STAINLESS STEEL 316L, Flexim 772240-44 MODULE,COMMUNICATION,MODBUS, Flexim 770221-2 0/4 TO 20 mA/ CURRENT OUTPUT, Flexim 770221-1 0/4 TO 20 mA/ CURRENT OUTPUT, Flexim 740255-T ADDITIONAL TEMPERATURE INPUT, Flexim 750G15-2A2 Clamp-on ultrasonic flowmeter. In the Energy version, the > F601 measures the instanta-neous thermal output of a system, i.e. ______ compact and easy to handle______ equally suitable for left and right-handed persons______ designed for industrial use______ multi-functional carrying and set-up handle______ degree of protection IP65______ handles also protect the edges______ low weight______ water and dust-tight; resistant against oil, many liquids, and dirt ______ QuickFix pipe mounting system forfast mounting of the transmitter in positions where a free hand for hol- ding is unavailable (e.g.formeasure- ments in great heights)______ > ______ integrated pipe wall thickness measurement______ ______ precise display of remaining capacity______ more than 14 hours of measurementwith lithium-ion batteries ______ no self-discharge, no memory effect ______ > extensive fluid and material database______ ______ extremely sturdy case; may even be used as a step______ proven FLUXUS > electronics with DSP and dual P, high sampling rate, adaptive signal processing______ increased accuracy in non-ideal con-ditions thanks to new algorithms, e.g.for the correction of pipe wall echoes and transducer positioning errors ______ intuitive stowing and finding of all components ______ FLUXUS FLUXUS In times of rising energy prices and envi-ronmental regulations, optimization of energy flow is a most crucial issue. Question - What is included in the F601 Rental Kit ?
Question - What are the Min/Max flow rates the F601 can measure ? Software FluxData, RS232 and USB cables Manual and quick-start guide > Please see the price lists for details on the scope of delivery and the accessories. The case's dimensions are in accordancewith airline requirements for carry-on luggage. ow measurement, FLUXUS F- ultrasonic flowmeters for liquids, G601 CA Energy - The portable flow meter for the measurement of compressed air, gases and heat quantities, FLUXUS BTU Serie Ultrasonic Flowmeter for measuring non-intrusive energy, Non-Intrusive Flow Measurement for Liquids and Gases in the Upstream Industry, FLUXUS HPI Series Non-Intrusive Ultrasonic Flow Measurement for the Hydrocarbon Processing Industries, Advanced Metering Technology Ultrasonic Flow Measurement in Gas Storage Operations, Non-Intrusive Flow Measurement up to 400C, FLUXUS WD / FLUXUS WS - Monitoring flow in Prestressed Concrete Cylinder Pipes (PCCP), FLUXUS WD The efficient flow monitoring solution. Question - Where are the Quick Start Guides for the F601 ? Answer The 4-20 mA outputs of the F601 can be user adjusted to any range of values youd like. The numerous improvements implemented were derivedfrom years of application practice. Measuring tape Power adapter / charging unit Coupling compound Mounting fixture for the transducers Wall thickness probe QuickFix pipe mounting system for the *Prices are pre-tax. Answer A document detailing the setup and management of the Data Logging features inside the F601 can be downloaded here. Question - What type of pipes will the F601 measure ? Question - Where are the Specifications for the F601 Flow Meter? Answer - The F601 is a dual-channel, dual mode clamp-on liquid ultrasonic flow meter capable of measuring liquid flow through two different pipes from inch to 256 inch in diameter, at the same time, in either Doppler or Transit Time modes. Answer Before making measurements with the F601 you must know the Outside Diameter and Wall Thickness of the pipe youre measuring, plus the approximate temperature of the fluid inside. Question - Where are the Manuals for the F601 ? Question What are the advantages of using the F601? detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results, User-friendly design Transducers available for a wide range of inner pipe, Probe for wall thickness measurement available Robust, water-tight (NEMA 4) transport case with com-, QuickFix for fast mounting of the flow transmitter in diffi-, Designed for industrial use in harsh environments, in gas, processing and natural gas extraction, chemical industry, and in the petroleum industry. Question Can the F601 function as an Energy Meter ? Question - What will I need to know before installing the F601 ? Question - What size pipes will the F601 measure ? During Covid-19 please call: 717-697-8546 or 717-514-4952. Answer The Rental Kit for the F601 will contain the F601 Flow Computer, a pair of Transducers to matchthe pipe sizes you indicate in the Rental Agreement Form, a battery charger/wall adapter, acoustic coupling compound, Mounting Chains and Mounting Clips, Instruction Manuals, Quick Start Guides, EESiData software for Windows, communications (RS232) cabling. Measurement with transducers mounted by the portable Variofix VP, Portable Ultrasonic Flow Measurement of Gas, Portable instrument for non-intrusive, quick ultrasonic flow measurement with clamp-on technology for all, Precise bi-directional and highly dynamic flow measure-, ment with the non-intrusive clamp-on technology, High precision at fast and slow flow rates, high tem-, Portable, easy-to-use flow transmitter with 2 flow chan-, nels, multiple inputs/outputs, an integrated data logger. > F601 is more than just anupgrade to the FLUXUS ADM 6725, an instrument which has proven itself in thousands of applications. Answer - When combined with the optional clamp-on temperature sensors, the F601 is capable of calculating generated or consumed energy in Watts or Jules. Once you input these values into the F601 it will recommend a transducer mounting separation distance. A single pair of S transducers will measure pipes from inch to 1 inches in diameter, Q transducers will measure pipes from 1 to 16 in diameter; M transducers will measure pipes from 4 to 100 inches in diameter and a pair of K transducers will measure pipes from 4 inch to 256 inches in diameter. the flow of heat or cold. Question How do I charge the batteries in the F601 ? Thanks to an integrat- edtotalizer, FLUXUS may also be used as ______Unmatched in performance, the handyand versatile ______ FLUXUS > F601 is ideallysuited for service and maintenance activi- ties, for instance when commissioning systems, for the maintenance and inspec-tion of permanently installed measuringinstrument, for checking pumps or control valves, or as a temporary substitute for defective instruments. Answer A three page document shows you the optimal mounting location for securing transducers onto pipes. Practical applications: Measurement on natural gas pipelines and in natural, Measurement of synthesized gas and injection gas Measurement for the gas supply industry Supervision of permanently installed meters, service.