xg50t12dm40u0 owner's manual


12 in, For Use With Rheem Tank Water Heaters, Includes Gasket, Instructions, Screws, Tinnerman Clips, Application Residential Tank Water Heater Installation.

If the supplied power cord is insufficient to reach a power outlet, a 30 foot power cord assembly is available as an accessory. liquefied petroleum (LP - Propane or butane) and Natural gas models LP and Natural gas have an odorant added to aid in detecting a gas leak. 10 Gas Supply. that you need! . schaltplan manuale schaltbild rparation reparaturanleitung

. Rheem HYDROGEN GAS IS EXTREMELY FLAMMABLE!! If you find damage, DO NOT install or attempt any repair to the water heater. To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system.

Replacement Parts For 38, 40, and, 50 gallon models using natural or LP gas. linhai Not valid email address, What is your message about : Installing the water heater Hot and Cold Pipe Insulation Installation Typical vertical piping arrangement For increased energy efficiency, some water heaters have been supplied with two 24 sections of pipe insulation. . Sufficient room to service heater. 12 in, For Use With Rheem Tankless Heaters, Includes Instructions, Application For Horizontal Venting, Flapper Vent Hood, Fits Brand Admiral, Amana, Caloric, Crosley, Estate, Hardwick, Inglis, Jenn-Air, Kenmore, KitchenAid, Magic Chef, Maytag, Modern Maid, Norge, Roper, Sears, Whirlpool, Includes Removable Bird Hood, Power Vent Motor 115V, For Use With Grainger Item Number 2HYW1, 2HYW2, 2HYW3, 2HYW4, 4E454, 4E455, 4E456, 4E457, 4E458, 4E459, 4E460, 4E461, 4E462, 4E463, 4E464, 4E465, 4E466, 4E467, 4E468, 4E469, 4E470, 4E471, 6RJV1, 6RJV2, 6RJV3, 6RJV4, 6RJV5, 6RJV6, 6RJV7, 6RJV8, 6RJV9, 6RJW0, 6RJW1, 6RJW2, 6RJW3, 6RJW4, 6RJW5, 6RJW6, 6RJW7, 6RJW8, 6RJW9, 6RJX0, 6RJX1, 6RJX2, 6RJX3, 6RJX4, 6RJX5, 6RJX6, 6RJX7, 6RJX8, 9E796, 9E797, 9E798, 9E799, 9E800, 9E801, 9E802, 9E803, 9E804, 9E805, Roof Cap, Fits Duct Size (In.) Please select your message about, What Is The Status Of Your Project? We have the Vent Kit, Horizontal, for 6FZN0 - 6FZN3 and Waterheater Vent Pipe, 36In L, 3In Dia.

Contact the manufacturer as detailed under the "IF YOU NEED SERVICE" section of this manual. No valve of any type should be installed between the relief valve and the tank. Tall 12 Year 40,000 BTU Energy Star Natural Gas Water Heater.

If additional information is required, refer to the section on If you need service..

disassembly . 3 in, 4 in, Flange Size (In.) ! Review the charts on the following pages first and you may not need to call for service. Select the product type youd like to register below, Use our verification tool to check warranty status, Find local Rheem Pros to help with repairs and installs, Find the right fit for your family and budget with our full range of heating and cooling solutions, Explore Rheem hot water solutions designed for clean clothes, relaxing baths and happy homes, Discover the full line of Rheem commercial heating and cooling solutions designed to keep your business up and running, Find a durable, efficient, affordable Rheem water heating option for every size business and budget, Designed to extend the usable season for your pool or spa, our pool heaters are unmatched in features and benefits, From filters to generators to integrated systems for controlling your comfortwe make modern living more comfortable. . Inspect the gas venting system and/or the chimney.

. T&P Insulation Installation For increased energy efficiency, this water heater has been supplied with a 2 3/8 section of T&P insulation.

. 3 5/16 in, Length (In.) tank provides ample hot water for households with 3 to 5 people, Natural gas water heater costs less to operate than electric models, Delivers 90 gal. .

. damage. . Save Listing| . Factory installed temperature and pressure relief valve and 3/4 in. Supplemental instructions for gas water heaters installed in potable/space heating applications Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedent over these instructions. . The electronic ignition system eliminates the standing pilot light, saves energy and monitors system performance. Performance Platinum Series Powered Damper, Sorry, no products were found with the filters you've chosen.

Be sure to read and follow the warnings outlined on the label pictured below. 3 + 1, heatingandairunits.com | All rights reserved | SiteMap, LoNox,Overheat Protection,Self Cleaning,Temperature Pressure Relief Valve,WiFi, Rheem XG50T12DM40U0 Tank Water Heater Natural Gas 5.0GPM indoor, Shop for Rheem and browse manuals and details of XG50T12DM40U0, Air Conditioning Repairman Mount Vernon, NY, Residential Air Conditioning Systems Mechanic, Due to ultra low-nox requirements from Air Quality Management Districts in the State of California, please confirm that your shipping zip code is not restricted from the use of items that do not meet local qualifications, 50 gal.

Technical Support Enter Your Email . Staple sales slip or cancelled check here. Installing the water heater G v H A D E V B B B C V L v ED FIX ED S CLO v LE RAB OPE F RA OPE BLE v B A M I X K X v B v v ED FIX D SE CLO J B V=Vent Terminal X = Air Supply Inlet rea Where Terminal Is Not Permitted US Installations 12 in. XE50T10HD50U0, XE50T12EC55U1, XG29T12XR60U0, XG50T12DM40U0, XG50T12DU36U1W, XG50T12HN38U1, XG55T12HE40U0, XG75T12ST76U0, Includes Gasket and Instructions, Pilot Assembly Replacement Kit, Material of Construction Metal, Wire, Brass, Manniglas, Height (In.)

Before You Call For Service Troubleshooting Tips Save time and money! Weve got everything to make your business go like Concentric Vent, 2" and Concentric Vent, 3". Such conversion could result in hazardous operating conditions.

.

Insulation Blankets WARNING: If local codes require external application of insulation blanket kits the manufacturers instructions included with the kit must be carefully followed. . This water heater incorporates a combustion shut off device that shuts the operation of the water heater down if undesirable combustion conditions occur, such as the presence of flammable vapors or blockage of the combustion air inlet openings. 5 1/2 in, Length (In.) Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. The branch gas supply line to the water heater should be clean, properly sized steel pipe or other approved gas piping material. Just Curious/Not Buying Anytime Soon

Its maintenance free combustion air intake system means there are no filters to clean and replace.

DANGER! Check with your local water utility company. Warning: This water heater is not suitable for use in manufactured (mobile) homes! Care and cleaning of the water heater Venting System Inspection The water heaters internal flue must be inspected periodically to be certain it is clean by removing the flue damper, draft hood, and flue baffle. If you are unable to open or download the manual then please use the HELP link up above for assistance. By continuing to use this website, you agree to our use of cookies. Insulation blankets, available to the general public, for external use on gas water heaters are not necessary. . . DO NOT use an extension cord for powering this water heater. Safety Information Safety Precautions.

. . Installing the water heater Wiring Diagram This water heater is factory installed with a 3 - pin 24 VAC wall transformer. 7 Water Supply Connections. of hot water in the first hour, 12 year limited warranty on tank and parts for your convenience, 3 year in home labor warranty for peace of mind, 0.67 energy factor indicates an energy star qualified water heater, Maintenance free - no filter to clean or replace, Electronic ignition system simplifies the startup process and eliminates the need for a pilot light, Electronic diagnostic gas valve monitors system performance, Requires standard 110-volt electrical outlet (3-prong grounded) for installation. READ ALL INSTRUCTIONS BEFORE USING. . Installing the water heater Inspect Shipment Carefully inspect the water heater for damage before proceeding with the installation. should be directed to the seller from whom it was purchased. Thermal Expansion Determine if a check valve exists in the inlet water line. READ ALL INSTRUCTIONS BEFORE USING. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. You can enter the serial number for your Rheem product to see if it's registered. A copy can be purchased from either the American Gas Association, 400 N. Capitol Street NW, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54. DANGER!

. . . Reinstall the flue damper and the draft hood. . Please, 1100 Abernathy Road, Suite 1700 Atlanta, GA 30328, Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the. . This label is also located on the water heater. 13 7/8 in, Cooper Sheath Material, Fits Residential and Commercial Electric, For Use With Mfr. .

5 FOR YOUR RECORDS Write the model and serial numbers here: # Installation Instructions Location. Failure to follow these warnings could result in serious bodily injury or death. Water Heater Location Close to area of vent.

observed and water heater not installed on carpeted floor. Other conditions, such as odorant fade, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak. A premium grade anode rod provides long lasting tank protection. 12 in, Width (In.) Hot water supply to house Hot water supply to heating unit From HOT outlet on water heater Tee fitting for vertical hot water supply lines.

FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions.

. Use & Care Manual ! Sufficient fresh air supply for proper operation of water heater. Air-Conditioning, Heating, & Refrigeration Institute. In the event the firm has moved, or is unavailable, refer to the telephone directory, commercial listings or local utility for qualified service assistance. Pay particular attention to the Safety Instructions. Email Listing | ! !

. You may then print out the Rheem XG50T12DM40U0 Natural Gas Water Heater manual or just save it to your device for safe storage. Air supply free of corrosive elements and flammable vapors. Typical horizontal piping arrangement Please install the insulation, according to the illustrations above, that best meets your requirements. The water heater is Energy Star qualified. . water connections are included with the water heater for easy installation. Product Name: Rheem XG50T12DM40U0 Tank Water Heater Natural Gas 5.0GPM indoor, Save Listing| .

. understand these instructions or any terms within it, seek professional advice.

If you need a Horizontal Vent Termination Kit 2 In.

Need Ultra Low NOx Commercial Water Heaters - Rheem has what you need now.

11 # You can find them on a label on the appliance. Water temperatures above 125F can cause severe burns or death from scalding. General Support . Operating the water heater CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). For more information, see our Privacy Statement. WARNING! IF YOU NEED SERVICE 1. All of our owner's manuals are in pdf format and can be opened using Adobe's Acrobat or some other pdf reader.

Please contact a Qualified Service Technician if this occurs. Share : Gas Valve LED Codes GAS VALVE LED Short flash once every four seconds Heartbeat, alternates bright/dim STATUS/PROBLEM Normal Operating Condition/ No Fault Condition Calling For Heat/No Fault Conditions PROBABLE CAUSE Water Temperature setpoint has been achieved SOLUTION None required Water temperature is below setpoint None required and burner is on Pilot tube restricted or damaged One Flash, three Control still operating/ Carbon build-up on pilot's electrode Replace Pilot assembly second pause, Gas Valve LED Codes cont: GAS VALVE LED STATUS/PROBLEM Six-Four Flashes, three second pause System in Lockout/ Flame sense out of sequence PROBABLE CAUSE Gas Control (Thermostat's) valve stuck open SOLUTION Replace Gas Control (Thermostat) Ensure that no flammable vapor(s) Gasoline or other flammable are present System in Lockout/ vapor(s) were detected Reset the Gas Control (Thermostat) Seven Flashes, three Presence of Flamma- Faulty Flammable Vapor Sensor using "ON/OFF" switch located on secon. 20112022 Zoro Tools, Inc. All rights reserved Share, Product Name: Rheem XG50T12DM40U0 Tank Water Heater Natural Gas 5.0GPM indoor.

. Please select status of your project, Verification Code : Webmaster Recognize this symbol as an indication of Important Safety Information! .

pecify type of gas (Natural or LP) S as marked on the rating plate. To determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. Should you have any problems reading or following the instructions in this manual, STOP, and get help from a qualified person. A condition known as stacking or layering can occur when a series of short and frequent hot water draws are taken. . The hottest temperature water will be at the top of the tank, closest to the outlet pipe delivering hot water to the home.

Gas Supply WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. . . Contact the service department to obtain and replace the power cord assembly that was shipped with the heater. . DANGER: Before manually operating the temperature and pressure relief valve, make certain no one will be exposed to the hot water released by the valve. IMPORTANT SAFETY INFORMATION. .

Care and cleaning of the water heater Draining the Water Heater ! If you do not. . Weve got everything to make your business go like Water Heater Vent Package, Side Wall and Horizontal Vent Termination Kit 3 In.. and recommendations for the proper installation and adjustment of the water heater; and two, It is imperative that all persons who are expected to install, operate or adjust this water heater read, the instructions carefully so they may understand how to perform these operations. CAUTION: Shut off gas to the water heater at the manual gas shutoff valve before draining water. Some people may not physically be able to smell or recognize this odorant. IMPORTANT SAFETY INFORMATION. Email Listing | . Operating the water heater Water Temperature Setting Maximum water temperatures occur just after the burner has shut off. 2. neighbors phone. Of specific interest should be any dents or damage to the draft hood and/or flue damper assembly. 9 Flue Damper . . . . 10-1/4 x 11, Cap Height (In.) Follow the gas supplier, The purpose of this manual is twofold: one, to provide the installer with the basic directions.

When reinstalling the flue baffle make certain it is hung securely by its collar at the top of the flue way.

Count on great prices, fast shipping and friendly service every time you order rheem protech water heater vents from Zoro.

water temperature Setting Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heaters gas control. Any questions regarding the operation, maintenance, service or warranty of this water heater. art description (as noted below) and P number of parts desired. All of our user guides and manuals are free to download, including this Rheem XG50T12DM40U0 owner's manual. Lighting the water heater Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water heater, as well as the warnings printed in this manual. Terms & Conditions Natural Gas Tall Water Heater comes with a 40,000 BTU/hour environmentally friendly Low-Nox burner that provides ample hot water for households with 3 to 5 people.

A 19 foot long length of wire is provided for easy access to an outlet.

It may save you time and money. .

A check valve located in the cold water inlet line can cause what is referred to as a closed water system. . or Horizontal Vent Termination Kit 3 In. Sales Questions

you can find them right here.

! . . Vent Hood, Characteristics Compatible with Rheem, Ruud, GE and Richmond Gas Water Heaters, Application To Ensures The Safe and Reliable Operation of Gas Water Heaters, Function Allows Venting Up to 50 Feet away from a Side Wall, Water Heater Vent Package, 115 V Voltage, 1.0 A Motor Amps, Characteristics Compatible with any Gas Water Heater Up to 60, 000 BTUs, Application Upgrade Water Heaters from Electric to Gas or in New Construction Where No Chimney Exists, Function Allows Venting Up to 75 Feet away from a Side Wall, Standards CSA Certified, Horizontal Vent Termination Kit 2 In., Material of Construction Plastic, Height (In.) Installation Checklist A. . . . Installing the water heater A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22/CSA 4.6, is supplied and must remain in the opening provided and marked for the purpose on the water heater. . Privacy Policy

A union or ANSI design certified semirigid or flexible gas appliance connector should be installed in the gas line close to the water heater. 4 3/8 in, Cap Width (In.) .

. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service agency. The Rheem Performance Platinum 50 gal.

Instructions For Placing a Parts Order All parts orders should include: he model and serial number of the T water heater from the rating plate. . . Ready To Buy

Local codes shall govern the installation of relief valves. READ ALL INSTRUCTIONS BEFORE USING. 6 1/4 in, Construction Material Steel, Black Epoxy Finish, For Use With Vent Terminations, Includes Built-in Bird Screen with Removable Damper, Heat Pump Riser, 3 in, Heat Pump Riser, 3 in, Gray, For Use With Air Handlers, Condensers, Heat Pumps, Gas Water Heater Control, NG, Capacity (BtuH) 36, 800, Fixed Pilot, Manifold Pressure Tap, 3/4 in NPT Mounting, 1/2 in NPT Inlet, 1/2 in Outlet, Water Heater Element, Medium-Watt Density, 208 V Voltage, 50/60 Hz, 5, 000 W Watts, Foldback Style, Insert Length (In.) Failure to do so can result in unsafe operation of the water heater resulting in property damage, personal injury, or death. . With Installation Instructions for the Installer Residential Gas - FVIR Certified Water Heaters WITH DAMPER & ELECTRONIC CONTROL Residential 38, 40, and 50 Gallon The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owneroperator, to explain the features, op.

. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage. DO NOT touch any electrical switch; do not, This product contains chemicals known to the State, Performance Platinum 50 gal. . CAUTION: For your safety, DO NOT attempt repair of gas piping, Gas Control (Thermostat), burners, vent connectors or other safety devices. Planning/Budgeting Download your Rheem XG50T12DM40U0 manual in pdf format. Do Not Sell My Personal Information, Shop for more tjernlund water heater vents, Shop for more diversitech water heater vents, Shop for more metal fab water heater vents, 20112022 Zoro Tools, Inc. All rights reserved, View More Products Related To Rheem Protech Water Heater Vents, commercial zone 30 gallon waste receptacle, beige. Indoors and protected from freezing Provisions made to protect area from water Proper clearance from combustible surfaces Combustible materials, such as clothing, temperatures. . . No.

- Select One - If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. It may have been installed in the cold water line as a separate back flow preventer, or it may be part of a pressure reducing valve, water meter or water softener. - Select One - 36 LP Gas Models . A cold water inlet line with no check valve or back flow prevention device is referred to as an open water system. All of the product manuals and owner guides we offer for download are in PDF format. .

The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. IMPORTANT SAFETY INFORMATION. Installing the water heater This water heater must be installed in accordance with these instructions, local codes, utility company requirements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. Brand: This Rheem Performance Platinum model is WiFi compatible allowing for remote monitoring of the water heater's operation (WiFi Module REWRA631GWH sold separately).