eps geofoam specifications


Click to enable/disable Google Analytics tracking. f?3-]T2j),l0/%b Post-consumer is defined as any material that is recycled after its intended end-use while post-industrial recovery includes EPS facility scrap that is recycled but never served its intended purpose as a packaging material or other end-use application. GeoFoam must not be exposed to flames or other ignition sources. Manufacturer Qualifications: Minimum 5 years experience manufacturing similar products. Pre-Installation Meeting: Convene at the project site a minimum of two weeks prior to starting work of this section to verify project requirements, substrate conditions, installation instructions and manufacturer's warranty requirements. No thermal drift. @L@[Dt%300 ,5 endstream endobj startxref 0 %%EOF 130 0 obj <>stream 4.1 This classification covers commonly manufactured types of GeoFoam as provided in Table 1. You can also change some of your preferences. ShelterFoam GPS: High-performance, closed cell, lightweight, mold and mildew resistant expanded polystyrene material used as rigid thermal insulation. Specific design considerations with GeoFoam may include strength, deformation, thermal conductivity and buoyancy. Please be aware that this might heavily reduce the functionality and appearance of our site. 4 0 obj hbbd```b``:"d;dmWv>0~ _[$! Section 32 10 00 - Bases, Ballasts, and Paving. 12.1 Unless otherwise specified in the purchase order or contract, the manufacturer or supplier shall furnish a letter of certification from an accredited and independent third party. 9.2 Aerial defect - damage to load bearing GeoFoam surfaces shall be limited to less than 20 percent of the equivalent load bearing surface area of a single block. 9 : 19727 57th Avenue. Check to enable permanent hiding of message bar and refuse all cookies if you do not opt in. You can check these in your browser security settings. Compressive Strength at 10 percent deformation per ASTM D1621: 100 psi. The values obtained by the oxygen index test (See Table I, and Section 10.2) do not necessarily indicate or describe the fire risk of the materials and are used in this specification primarily to distinguish between GeoFoam formulated with flame retardants and those not so formulated. We may request cookies to be set on your device. Manufacturing quality control data and product validation test results shall be retained for review and inspection as required. By continuing to browse the site, you are agreeing to our use of cookies. <> ShelterFoam 100: High-performance high-density insulation consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS). EPS Geofoam: Provide EPS geofoam, structural geotechnical engineering fill blocks, as manufactured by Shelter Enterprises Inc. in locations and configurations as shown on the drawings, and to meet the following properties: EPS 15, 1.0#, Type I in accordance with ASTM D6817: Minimum Density: 0.90 pounds per cubic foot (14.4 kilograms per cubic meter). It is the user's responsibility to specify density and design requirements and to obtain supporting documentation from the material supplier. 7.5 Curing - GeoFoam must be cured at the manufacturing plant before shipment. Changes will take effect once you reload the page. 7.05 Blocks shall be cut using a hot wire. Click to enable/disable _gat_* - Google Analytics Cookie. EPS Geofoam for Use as Structural and Nonstructural Void Fill. General Description, 2. We need 2 cookies to store this setting. E. Puyallup, WA 98375 800.248.5995 HYPERLINK "http://www.Insulfoam.com" www.Insulfoam.com HYPERLINK "mailto:geofoam@Insulfoam.com" geofoam@Insulfoam.com Specification for Insulfoam GF (Geofoam) [Items in italics are editorial comments that need to be removed when the specification is edited.] PART 6 SUBGRADE PREPARATION 6.1 Clear and grub site. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 2.03 Geofoam blocks shall have the following physical properties: [Editorial Note: Edit out the types of EPS not needed for this specific project by deleting the appropriate columns from the following table.] 8. Verify engineered depths, product thicknesses, and other conditions which would affect installation. At 1% Deformation: Minimum 5.8 psi, 835 psf (40 kPa). These cookies are strictly necessary to provide you with services available through our website and to use some of its features. 7. Physical properties remain stable over entire service life. Store and handle materials in accordance with the manufacturers instructions to avoid damage. Often used in residential slab construction when hydronic heat is used.

6.1 GeoFoam shall be of uniform density and free of continuous voids. 13.1.4 Weight, and Lot number, to include resin source and type. Each connector shall have a lateral holding strength of at least 27.22 kg (60 lbs) when tested with an EPS15 Geofoam. EPS geofoam is approximately 1% the weight of soil and less than 10% the weight of otherlightweight fill alternatives. 7.3 GeoFoam Types - Table I describes the commonly available types of GeoFoam; however, it does not cover all available densities that can be manufactured. The leveling pad material shall be sand, pea gravel or any locally available permeable material approved by the Engineer of record. Installer Qualifications: Minimum 2 years experience installing similar products of the scope and complexity required for this project. 5.05 Damage to Geofoam shall be corrected as follows: Slight damage less than .0283 m3 (1 ft3) may be left in place as is. Geofoam blocks not meeting the damage criteria may be cut to eliminate the excessive damage and the remaining, undamaged, portion of the block may be used within the fill, provided the undamaged portion of the block meets all other design requirements. 93 0 obj <> endobj 109 0 obj <>/Filter/FlateDecode/ID[<1ECBC95741C40F40A9A96EEC40500ED2><580032D033E5408DBE96321471EE8F8D>]/Index[93 38]/Info 92 0 R/Length 88/Prev 863610/Root 94 0 R/Size 131/Type/XRef/W[1 3 1]>>stream See construction foam used in hundreds of applications. In order to avoid continuous joints, each subsequent layer of blocks shall be rotated on the horizontal plane 90 degrees from the direction of placement of the previous layer placed. 6.2 Dewater site as required.

A u H '@ " oE E 0 F I@ f K f K D A f A 6 6 6 E E f 6 6 6 F K 6 6 6 6 6 6 6 6 6 . At 10% Deformation: Minimum 40.0 psi, 5760 psf (276 kPa). Does not retain moisture and maintains physical properties even under extreme environmental conditions, Reflects radiant heat energy, reduces thermal conductivity, and. 10.3 Dimensions - verify specified dimensions and tolerances, as prescribed in Test Method D-1622 and section 8.2 of this specification. Qualification Data: Submit manufacturer and installer qualifications. The publications are referred to in the text by the basic designation only. <>>> Conductance per Inch: per ASTM C518 or ASTM C177, At 25 degrees F ( degrees C): 0.196 BTU/hr sq ft F, At 40 degrees F ( degrees C): 0.198 BTU/hr sq ft F, At 75 degrees F ( degrees C): 0.217 BTU/hr sq ft F, R-Value Resistance: per ASTM C518 or ASTM C177. Meets or exceeds requirements of ASTM D6817. The following cookies are also needed - You can choose if you want to allow them: You can read about our cookies and privacy settings in detail on our Privacy Policy Page. endobj Nominal Density (description /classification name) per ASTM C303: 1.00 lb/ cu ft (16.0 kg/cu m). Unless otherwise specified in the contract, GeoFoam shall be cured for a minimum of 3 days before delivery and inspection. Submit under provisions of Section 01 30 00 - Administrative Requirements. Water Vapor Permeability: per ASTM E96: 4.0 maximum permeability per inch. Comply with manufacturer's ordering instructions and lead time requirements to avoid construction delays. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 7.06 Because of the light unit-weight of the geofoam fill, it is the Contractor's responsibility to provide temporary weighting and/or guying as necessary until all the blocks are built into a homogeneous mass, and the pavement section as well as any soil cover are in place. Subgrade Preparation, 7. Buoyancy Force: 61.5 pounds per cubic foot (980 kilograms per cubic meter). 8.1 Availability - The GeoFoam materials covered by this specification are commonly available in the size range shown in Table II. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer. At 5% Deformation: Minimum 24.7 psi, 3560 psf (170 kPa).

Water Vapor Permeance per ASTM E96: 2.5 maximum. At 25 degrees F (minus 3.9 degrees C): 5.1. [Editorial Note: If a load distribution slab is not utilized edit out the following.] Click to enable/disable Google reCaptcha. Color: Silver-Gray color, due to the high purity graphite that is contained within the polymer intercellular substance of the foam board. 7.05 When needed to prevent blocks sliding during embankment construction, Insulgrip plates or a urethane adhesive such as Flexible FastTM should be placed between horizontal layers of blocks. Regional Materials: Submit documentation of manufacturing plant location relative to project location if less than 500 miles (800 km). [Editorial Note: Insert the appropriate section number in the preceding reference] PART 7 PLACEMENT 7.01 EPS Geofoam fill shall be placed to the lines and grades shown in the plans and as directed by the Engineer. Examine and measure installation areas and subgrade conditions are prepared to receive geofoam to confirm site conditions are within the manufacturers limits. A 200 mm (8 in) leveling pad shall be constructed over the prepared grade. PART 8 CONNECTORS 8.01 Connectors shall be galvanized steel multi-barbed connectors or a urethane adhesive. This figure includes 63 million pounds of post-consumer packaging and 55.7 million pounds of post-industrial recovery. Prior to delivery of Geofoam block fill to the project site, the Contractor shall review and be thoroughly knowledgeable with the manufacturer's care and handling recommendations. The location and type of connectors. 1.3 GeoFoam shall be protected from certain chemicals, fire sources, extended exposure to sunlight, and concentrated loads. 8.2 Dimensional Tolerances - Unless otherwise specified, the acceptable length, width, thickness, squareness and flatness tolerance for GeoFoam shall not exceed + 0.5 per cent.

E., Puyallup, WA 98375, Phone: 253-248-5995 Fax: 253 383-7100. At 10% Deformation: Minimum 10.2 psi, 1470 psf (70 kPa). There are components in this specification that may not be relevant for particular jobs. They seem to always deliver when I'm in a crunch and don't have the luxury of time. Proposed placement methods. At 25 degrees F (minus 3.9 degrees C): 5.5. Install in accordance with the manufacturer's current published instructions, and details and drawings issued for the project. Insulfoam Manufacturing Facility, 3401 W. Cocopah Street, Phoenix, AZ 85009, Phone: 602-269-2272, Fax: 602-269-8402 Insulfoam Manufacturing Facility, 1155 Business Park Drive, Building A, Dixon, CA 95620, Phone: 707-678-6900, Fax: 707-678-2962 Insulfoam Manufacturing Facility, 4500 South Frontage Road, Lakeland, FL 33815, Phone: 863-688-8879, Fax: 863-682-1702 Insulfoam Manufacturing Facility, 501 S. Emerald Road, Tooele, UT 84074, Phone: 800-735-4621, Fax 800-769-6065 Insulfoam Manufacturing Facility, 12601 East 33rd Ave, Unit 110, Aurora, CO 80011, Phone: 303-366-7730, Fax: 303-366-7742 Insulfoam Manufacturing Facility, 628 Western Drive, Anchorage, AK 99501, Phone: 907-279-9407, Fax: 907-279-9011 Insulfoam Manufacturing Facility, 2000 Summit View Drive, Smithfield, PA 15478, Phone: 855-207-0087, Fax: 855-246-9936 Insulfoam Manufacturing Facility, 1057 Sunburst Lane, Mead, NE 68041, Phone: 402-624-6611, Fax: 402-624-2325 2.05 No product substitutions permitted. Does not readily absorb moisture from the environment. You are free to opt out any time or opt in for other cookies to get a better experience. PART 10 PAYMENT 10.01 Payment for the completed EPS Geofoam fill-work, which includes all equipment, labor and materials necessary to furnish and install the EPS Geofoam fill and connectors according to the plans and this specification, will be made in accordance with Section [xxx.xx] [Editorial Note: insert the appropriate section number in the preceding reference] for each of the following bid items: Type EPS12 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS15 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS19 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS22 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS29 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS39 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS46 Geofoam Lightweight Fill, per cubic meter (yard) [Editorial Note: Delete the Types of Geofoam that are not used on this specific project from the list above.] No thermal drift. Position the next foam block as specified and seat firmly before placing subsequent blocks. No gaps greater than 20 mm (0.07ft) will be allowed on vertical joints. Otherwise you will be prompted again when opening a new browser window or new a tab. 9.1 Defects - GeoFoam shall have no defects that will adversely affect its service and workability qualities. 7.08 The embankment material, in areas beyond the lateral distances necessary to protect Geofoam from damage, shall be compacted according to [Editorial Note: Insert the Applicable specification section for soil compaction] Specification Section [xxxx.xx]. Often used as void fill in green roof construction. Water-Resistant. The drawing shall clearly indicate the size, type, location and orientation of all Geofoam blocks. N _rels/.rels ( j0@QN/c[ILj]aGzsFu]U ^[x 1xpf#I)Y*Di")c$qU~31jH[{=E~ Do not begin installation until substrates have been properly prepared. Oxygen Index per ASTM D2863: 24.0 percent volume. Standards Compliance: Recognized by the International Code Council Evaluation Service (ICC-ES). 3 0 obj Submittals, 5. hb```c``*d`a`x "@QS EPS 39, 2.5#, Type XIV in accordance with ASTM D6817: Minimum Density: 2.40 pounds per cubic foot (38.4 kilograms per cubic meter). Do not use where combined loads will exceed 1570 pounds per square foot with a safety factor applied. The construction of roadways and retaining walls. At 10% Deformation: Minimum 19.6 psi, 2820 psf (135 kPa). Manufacturer must have a UL classification in category BRYX. They can be deleted as necessary. 7.03 The finished surface of the Geofoam on side slopes that receive soil cover shall be constructed to within a tolerance of plus 90 mm (0.30 ft) to minus 90 mm (0.30 ft) of the indicated grade. Click to enable/disable _ga - Google Analytics Cookie. At 5% Deformation: Minimum 13.1 psi, 1890 psf (90 kPa). Recycled Content: Submit documentation of pre-consumer and post-consumer recycled content including manufacturing process recovery of recycled materials. 7.04 Blocks placed in a row in a particular layer shall be offset .6 m (2.0 ft) relative to blocks placed in adjacent rows of the same layer as shown on the plans. 4.03 The Contractor shall submit to the Engineer a Manufacturers Certificate of Compliance for the first 76 m3 (100 yd3) and for every 1147 m3 (1500 yd3) thereafter before the Geofoam is delivered to the site. . Jesse Moreno jesse@foamconcepts.net office:(714) 693-1037 cell: (714) 863-9452, Steve Ross Steve@foamconcepts.net office:(714) 693-1037, Foam Concepts, Inc. 4729 E Wesley Drive Anaheim, CA 92807 Toll Free: (888) 693-1037 geofoam@foamconcepts.com, Hours of Operation Mon to Fri: 7:00 AM4:00 PM Saturday: Closed Sunday: Closed. Accordingly, materials shall be presented in lots of 151 or more for normal or tightened inspection, as required. ' )n Ejfnz'|VCi}"3b_halNS'0]5XMm(SMSyk l]r-*'BpeY[S(`*-ELBW`Wpu}-,znYpifdAp.fm1T:@y%A5L+"f@]?paIlTO$cE$_ mDNP"'NeKKIY:_^} $K4PR"6i-^8tO{5.9"a[NZiwhe^?`%JJWPqhgC(aV'a83$P*qjenC?AY,)VdpL@H|"?G>ohXthV:\+b2K"K?iK&"3XI8*f9?f":)P w(PB*r==`A(u_|#6uj[Zk1k:8f nBJ`SOYPydRVA1I?QD~44(\PDFT@}Rc=w%}^45peu9R:SfS%5n(>}"Bz.{(.#* $AJ HNSPf5d_#)asQd The manufacturer or supplier shall have the right to re-inspect a rejected shipment and resubmit selected units for acceptance under tightened inspection. 4.04 The Certificate of Compliance shall include current inspection reports showing that the Geofoam manufacturer is in compliance with a UL follow-up service program for both flame and physical properties. 4.02 Prior to the delivery of the EPS Geofoam blocks, the Contractor shall furnish the Engineer with a copy of manufacturers test reports or a third partys certified test report showing that the Geofoam blocks meet the physical properties and standards listed above in Table 1. PART 4 SUBMITTALS 4.01 Prior to the start of work the Contractor shall submit for approval the following: A plan sheet showing a profile and section view of the proposed embankment. 3.1. Click on the different category headings to find out more. Minimum values of density, strength and modulus in uniaxial compression, flexural strength and oxygen index shall be in accordance with Table 1. The computed density must meet or exceed the minimum value for the GeoFoam type given in Table 1. Water Absorption, Maximum Total Immersion: 3 percent. TABLE 1: Physical Properties of EPS Geofoam TYPE - ASTM D6817EPS12EPS15EPS19EPS22EPS29EPS39EPS46Density, min., kg/m 3, ( lb/ft3 )11.2(0.70)14.4(0.90)18.4(1.15)21.6(1.35)28.8(1.80)38.4(2.40)45.7 (2.85)Compressive Resistance@ 1% deformation, min., kPa (psi)15(2.2) 25(3.6) 40(5.8) 50(7.3) 75(10.9) 103(15.0) 128 (18.6) Flexural Strength min., kPa (psi)69(10.0)172(25.0)207(30.0)276(40.0)345(50.0)414(60.0)517 (75.0)Elastic Modulus, min., kPA (psi)1500 (220)2500 (360)4000 (580)5000 (730)7500 (1090)10300 (1500)12800 (1860)Oxygen Index, min.,volume %24.024.024.024.024.024.024.0Geofoam should be considered combustible and should not be exposed to open flame or any source of ignition. At 5% Deformation: Minimum 35.0 psi, 5040 psf (241 kPa). Protect installed products and surface finishes from damage during construction. Contains no formaldehyde or ozone-depleting HCFCs. Physical Requirements - as given in Table 1 and 2. endobj Nominal Density (description /classification name) per ASTM C303: 1.50 lb/ cu ft (24.0 kg/cu m). Blocks in conformance with contract requirements can be used to make required fills. Availability and Dimensional Tolerances. This site uses cookies. Buoyancy Force: 60.0 pounds per cubic foot (960 kilograms per cubic meter). Water Absorption by total immersion per ASTM C272: 1.1 percent by volume, maximum. All blocks shall be within tolerances of 0.5% of respective height, width and length dimensions. <> At 5% Deformation: Minimum 43.5 psi, 6260 psf (300 kPa). 9.4 UV degradation - pressure washing may be used to remove discoloration and dusting of GeoFoam caused by extended exposure to sunlight and to restore interface friction strength, if required. Product Data: Submit manufacturer's product data and technical bulletins including materials, profiles, physical properties, and accessories for each product to be used, including: Preparation instructions and recommendations. Test Reports: Submit summary of tests that products comply with specified performance requirements. No more than 76 m3 (100 yd3) of Geofoam shall be manufactured until the Engineer has approved the material. More than 118 million pounds of EPS were recycled during calendar year 2016. EPS Geofoam Reduces the Lateral Load on a Retaining Wall, EPS29 is a low density EPS Geofoam weighing just 1.80 pounds per cubic foot (28.8 kg/M3). Minimum Density: 1.80 pounds per cubic foot (28.8 kilograms per cubic meter). But this will always prompt you to accept/refuse cookies when revisiting our site. Connectors, 9. exceeding the "moderate" category) shall be replaced with Geofoam blocks which meet the damage material design properties. D-2863 Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-like Combustion of Plastics. At 10% Deformation: Minimum 16.0 psi, 2300 psf (110 kPa). Deliver products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation. Approved Material: Insulfoam Manufacturing Facility, Headquarters, 19727 57th Avenue. Manufacturer must also maintain a UL classification in category QORW that ensures physical properties in accordance with ASTM D 6817. l`j0W*b~)60aAF)A1W(^+:H3 W"v'D #i endstream endobj 94 0 obj <>/Metadata 10 0 R/Pages 91 0 R/StructTreeRoot 24 0 R/Type/Catalog>> endobj 95 0 obj <>/MediaBox[0 0 612 792]/Parent 91 0 R/Resources<>/ProcSet[/PDF/Text/ImageC]/XObject<>>>/Rotate 0/StructParents 0/Tabs/S/Type/Page>> endobj 96 0 obj <>stream At 1% Deformation: Minimum 3.6 psi, 520 psf (25 kPa). C-203 Test Methods for Breaking Load and Flexural Properties of Block Type Thermal Insulation, C-390 Criteria for Sampling and Acceptance of Preformed Thermal Insulation Lots, C-578 Standard Specification for Rigid Cellular Polystyrene Insulation, D-1621 Test Method for Compressive Properties of Rigid Cellular Plastics, D-1622 Test Method for Apparent Density of Rigid Cellular Plastics.