honeywell barcode scanner 1900 manual


The user may find the fol- lowing booklet helpful: Something About Interference. This is available at FCC local regional offices. The breakdown of the row checksum: D85 Description 1 Weight Scheme: 13 (see Checksum Table page 15) 0 0 Checksum Type: Row (see Checksum Table page 15) 0 Translation of the sum to binary code 0 1 0 0 The breakdown of the block checksum: DFF Description 1 Weight Scheme: 137 (see Checksum Table page 15) 1 1 Checksum Type: Block (see Checksum Table page 15) 1 Translation of the sum to binary code 1 1 1 1 The top line checksum is the 6 at the end of the line.

Enable Price Field Template You can enable multiple Pre-Defined OCR templates along with the Price Field template. The template reads both OCR-A and OCR-B fonts. Example: You need to read 8 numeric digits in either OCR-A or OCR-B: 12345678 The string would be: 1 3 5 5 5 5 5 5 5 5 0 The breakdown: Control Code Description 1 New Template Code 3 Both OCR-A and OCR-B font 5 Wildcard: Numeric - 8 times 5 5 5 5 5 5 5 0 End of Template A template may contain multiple distinct templates all within the same string. honeywell 1952 xenon manual quick start manualslib manuals 65 41 A 97 61 a 22 66 42 B 98 62 b 23 # 67 43 C 99 63 c 36 24 $ 68 44 D 100 64 d 37 25 % 69 45 E 101 65 e ACK 38 26 & 70 46 F 102 66 f 07 BEL 39 27 71 47 G 103 67 g 08 BS 40 28 ( 72 48 H 104 68 h 9 09 HT 41 29 ) 73, Dec Hex Char Dec Hex Char Dec Hex 160 A0 161 A1 Char Dec Hex Char 192 C0 224 E0 193 C1 225 E1 128 80 129 81 130 82 162 A2 194 C2 226 E2 131 83 163 A3 195 C3 227 E3 132 84 164 A4 196 C4 228 E4 133 85 165 A5 197 C5 229 E5 134 86 166 A6 198 C6 230 E6 135 87 167 A7 199 C7 231 E7 136 88 168 A8 200 C8 232 E8 137 89 169 A9 . Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equip- ment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell. OCR Programming Codes We recommend that you enter OCR Templates using serial commands. This device may not cause harmful interference. Check for damage during shipment.

Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte. Prefix to All Symbologies, CCB01-010BT Charge Base Product Specifications, Replacing Cables and Batteries in Cordless Systems, Online Product Service and Repair Assistance, Barcode Reader Honeywell XENON 1902 User Manual, Barcode Reader Honeywell 1900GSR-2 User Manual, Barcode Reader Honeywell Xenon 1900 User Manual, Barcode Reader Honeywell Xenon 1910 User Manual, Scanner Honeywell Xenon 1900 Quick Start Manual, Barcode Reader Honeywell Xenon 1910 Quick Start Manual, Barcode Reader Honeywell Xenon 1900 Quick Start Manual, Barcode Reader Honeywell Xenon 1902 Quick Start Manual, Scanner Honeywell Xenon 1932 Quick Start Manual, Scanner Honeywell XENON 1902G-BF Quick Start Manual, Scanner Honeywell Enhanced Xenon 1902H Quick Start Manual, Page 23: Connecting With Rs232 Serial Port, Page 29: Chapter 2 - Programming The Interface, Page 34: Verifone Ruby Terminal Default Settings, Page 35: Gilbarco Terminal Default Settings, Page 36: Ncr Bioptic Aux Port Configuration, Page 37: Wincor Nixdorf Beetle Terminal Default Settings, Page 51: Rs232 Word Length: Data Bits, Stop Bits, And Parity, Page 54: Scanner To Bioptic Communication, Page 57: Chapter 3 - Cordless System Operation, Page 58: Communication Between The Cordless System And The Host, Page 62: Scanner Led Sequences And Meaning, Page 63: Base Power Communication Indicator, Page 79: Application Work Group Selection, Page 80: Resetting The Custom Defaults: All Application Work Groups, Page 84: Bluetooth/Ism Network Activity Examples, Page 87: Chapter 4 - Input/Output Settings, Page 112: To Clear One Or All Prefixes Or Suffixes, Page 113: To Add A Carriage Return Suffix To All Symbologies, Page 121: Ascii Conversion Chart (Code Page 1252), Page 125: Data Format Non-Match Error Tone, Page 137: Code Page Mapping Of Printed Barcodes, Page 139: Interleaved 2 Of 5 Message Length, Page 143: Straight 2 Of 5 Industrial (Three-Bar Start/Stop), Page 144: Straight 2 Of 5 Iata (Two-Bar Start/Stop), Page 178: Chinese Sensible (Han Xin) Code, Page 198: Intelligent Signature Capture - Imgbox, Page 216: Installing Ezconfig From The Web, Page 261: Ccb01-010Bt Charge Base Product Specifications, Page 270: Troubleshooting A Cordless System, Page 271: Troubleshooting A Cordless Scanner, Page 275: Online Product Service And Repair Assistance, Page 282: Code Page Mapping Of Printed Barcodes. Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to oper- ate this equipment.

The other weight schemes multiply the character value by a repetitive weight value that helps in identifying characters that have had their column locations switched. Multiple Pre-Defined OCR Templates You can enable combinations of Pre-Defined OCR Templates by scanning one the following bar codes. Scan the OCR Off bar code to disable OCR reading. Use only shielded data cables with this system.

To discard your template, scan Discard OCR Template.

hbbd``b`$o@D6$@i:"b0 !Hl cd2;:Fgd{` YMK=^[+"T=10*(vGLhTNf0k5Lr|!B/zsnb_i1!] $JuH;Jt>Md[w#?FbOJKTSuhrJy&^Aq^cnLWB0YFc\mK]?`0 (=]'PnKCm2NyI"Oj F@vr|V11P7Nl_4ZG%X[JQWK7O=#[w6H3;iP4xE`>vRh:n;SolS:V=.^)En{V1 \j.

The following examples can also be read when the Price Field Template is enabled: C6712 $801E C0217 4399E C0823 31559E C0331 706213E Scan the following bar code to enable the Price Field Template. Enabling OCR Reading Scan one of the following bar codes to program your scanner to read OCR in either Normal Video (black characters on a white background), Reverse Video (white characters on a black background), or Both Normal and Reverse Video.

Product specifications, dimensions, warranty, and customer support information are also included. It protects all the characters in the template, including the first line. As you move to the left of the checksum, the weight value is updated to the next member of the sequence. Online Technical Assistance You can also access technical assistance online at www.honeywellaidc.com.

The checksum character always starts with a weight of 1. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This template reads both OCR-A and OCR-B fonts.

Increase the separation between the equipment and receiver. Report damage immediately to the carrier who delivered the carton.

scanner symbol ls2208 zebra barcodes scanners manual user found instructions usb printers drawers receipt overview cash while Readmore and Download Honeywell Xenon 1900 User Guide Manual PDF Below, Honeywell Honeywell Owner Guide Honeywell User Guide Honeywell Operating Manual Honeywell User Manual.

The following examples can be read when the MICR E-13B Template is enabled: 123456789 01235 123456789 193412454 98765 568123977 67891788 70 Note that in the third example, there will be 2 separate output results because of the 4 space gap between the first and second fields. The scanner will read OCR-A, OCR-B, MICR E-13B, and SEMI Font, in a 6 to 60 point OCR typeface. The breakdown: Control Code Description 1 New Template Code 2 OCR-B font 5 Wildcard: Numeric F Variable Character Repeat - 5 min, 7 max 05 07 0 End of Template Groups In a given character position, you must specify which values a text character may take. The X at the end of the line is a mod 36 block checksum with 137 weighting. A Defined Group B In Line Group Start C In Line Group End D Checksum E Fixed Character Repeat F Variable Character Repeat x ASCII Hex Value Save OCR Template Discard OCR Template 20, ASCII Conversion Chart Dec Hex Char Dec Hex 0 00 NUL 32 20 1 01 SOH 33 21 2 02 STX 34 3 03 ETX 35 4 04 EOT 5 05 ENQ 6 06 7 8 Char Dec Hex Char Dec Hex Char 64 40 @ 96 60 ! This unit has been tested with cables less than 3 meters.

Disclaimer Honeywell International Inc. (HII) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. $ Following the currency character, a numeric grouping of 3, 4, 5, or 6 digits is followed by a terminating letter 'E.' 2D barcode scanner Xenon 1900 HD USB Schwarz Imager Black Hand-held USB. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equip- ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: If necessary, the user should consult the dealer or an experienced radio/ television technician for additional suggestions. that produce MICR output, so you should check for partial reads of MICR text where only part of the targeted MICR string is actually in the image presented to the scanner. After you open the shipping carton containing the product, take the following steps: A scanner or a cordless base can be connected to the USB port of a com- puter. The byte immediately following the Checksum control code (D) defines the type of checksum that will be used: Checksum Table Bit Position(s) Meaning 7,6: Weight Scheme 00: Weight Scheme: 1 01: Weight Scheme: 12 10: Weight Scheme: 13 11: Weight Scheme: 137 5: Checksum Type 0: Row 1: Block 4-0: Modulo Value Checksum Modulo - 5 Row Checksums (0) perform a checksum calculation on all characters preceding them up to the first character on the same row. Make sure the items in the carton match your order. Operation is subject to the following two conditions: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules.

315 0 obj <>stream The breakdown: Control Code Description 1 New Template Code 1 OCR-A font 5 Wildcard: Numeric - 4 times 5 5 5 2 New Line 8 Wildcard: Any (including space) - 8 times 8 8 8 8 8 8 8 0 End of Template Repeating Characters To simplify the creation of user templates, the Fixed Character Repeat control code may be used to repeat a character a specified number of times. 5 G F E (1x5) + (3x16) + (1x15) + (3x14) = 110 Again, a value is obtained that is a multiple of 10, validating this row checksum. The information in this publication does not represent a commitment on the part of HII.

endstream endobj startxref

However, there is no guarantee that interference will not occur in a particular installation.

Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. FzbmF*;^0.XjEg@1 Note: Once OCR reading is enabled, you must select a Pre-Defined Template, page -3, or create a Custom OCR Template, page -8, in order to read OCR characters. 260 0 obj <> endobj

Custom OCR Templates You can create a custom template, or character string that defines the length and content of OCR strings that will be read with your scanner. Each row can have up to 50 characters, with up to 18 rows in a template, with a maximum of 320 characters.

Passports and Format-A visas each consist of two rows of 44 OCR-B characters. Table of Contents OCR Programming OCR Defaults .. 1 Enabling OCR Reading .. 2 Working Orientation . 2 Pre-Defined OCR Templates .. 3 Passport Template .3 ISBN Template .4 Price Field Template .. OCR Programming The following instructions are for programming your scanner for optical character recognition (OCR).

Save the shipping container for later storage or shipping. Any specific ASCII value, wildcard, or group can be repeated. However, you can also enter them by scanning the Enter OCR Template bar code, followed by the OCR Programming Codes, followed by a Menu Save code. Connect the appropriate interface cable to the device first, then to the computer.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. The breakdown: Control Code Description 1 New Template Code 3 Both OCR-A and OCR-B font 5 Wildcard: Numeric E Fixed Character Repeat - 8 times 0 8 0 End of Template Variable Character Repeat The Variable Character Repeat control code may be used to repeat a count for a character a variable number of times. Cables greater than 3 meters may not meet class B performance. Reorient or relocate the receiving antenna. %PDF-1.6 % Go to www.honeywellaidc.com and download the EZConfigScanning software tool. Default = Upright. To reduce the overall size of templates, you may define common groups of ASCII characters and then use the defined group control character rather than repeating the same sequence over and over.

If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. The breakdown (dark box indicates group definition): Control Code Description 1 New Template Code 2 Both OCR-A and OCR-B font 3 Defined Group 001 Group ID x41 ASCII hex value for A x42 ASCII hex value for B x43 ASCII hex value for C 5 Numeric Digit 4 Define Group End 5 3 Numeric Digits 5 5 A001 Defined Group, ID 001 0 End of Template See the ASCII Conversion Chart on page 21 for character to hex conversions. * Upright Vertical, Bottom to Top Upside Down Vertical, Top to Bottom Pre-Defined OCR Templates Passport Template The Passport Template may be used to read passports, visas and official travel documents based on the ICAO standard. This device complies with part 15 of the FCC Rules. Consult the dealer or an experienced radio or television technician for help. Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc. This equipment generates, uses, and can radi- ate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. TupBO!CZPSC:TK]=wWY2D\5SFw}p8pi]6N%|C {X${eg@{he^82X|v'1(|-Ie`|tc%+>#9^ =>i?$Vw)Q3d} . FCm8$(%FhI+McTb_?LG+uc]Ytylu- N#

its position. Honeywell supplies a free software tool for entering programming commands serially. Cordless area-imaging scanner and charge bases (18 pages), Battery-free wireless area imaging scanner and charge base (17 pages), Cordless area-imaging scanner for healthcare (16 pages), Manual will be automatically added to "My Manuals", Programming the Interface - Plug and Play, Verifone Ruby Terminal Default Settings, Wincor Nixdorf Beetle Terminal Default Settings, RS232 Word Length: Data Bits, Stop Bits, and Parity, Communication between the Cordless System and the Host, Out of Range and Back into Range with Batch Mode on, Resetting the Custom Defaults: All Application Work Groups, Changing the Scanner's Bluetooth PIN Code, Minimizing Bluetooth/Ism Band Network Activity, To Add a Carriage Return Suffix to All Symbologies, Intercharacter, Interfunction, and Intermessage Delays, Straight 2 of 5 Industrial (Three-Bar Start/Stop), Straight 2 of 5 IATA (Two-Bar Start/Stop), To Add a Test Code I.D.

An asterisk (*) next to an option indicates the default setting. Enter the password to open this PDF file: Honeywell TC500A Commercial Thermostat User Gude, Honeywell RTH111 Digital Non Programmable Thermostat User Manual, Honeywell Thermostat th6220d1002 Installation Manual, Honeywell TH8320R1003 Installation Manual, Honeywell Smart Programmable Thermostat RTH6500WF Smart Series Manual, Honeywell T4 pro Series Thermostat Manual, Honeywell Thermostatic Radiator Valves and Actuators, Honeywell T8624D IV Deluxe Chronotherm Thermostat Manual, Honeywell RLV4305 Programmable Thermostat RLV4305A1000 Manual, Honeywell T6 Pro Hydronic Programmable Thermostat User Guide, Honeywell T6 Pro Hydronic Programmable Thermostat Manual, Honeywell TH8321WF1001 Installation Guide, Honeywell Pro 4000 Series/TH4110D1007 Owner's Manual, Honeywell Lyric Round Wi-Fi Thermostat Manual, Honeywell RTH111B1024 Quick Installation Guide, Honeywell RTH2300B1038 Quick Installation Guide, Honeywell RTH230B Programmable Electronic Thermostat Installation Manual and User Guide.